Panasonic A4P Series 사용자 설명서

다운로드
페이지 232
100
How to Use the Console
Clearing of Absolute Encoder
Only applicable to the system which uses absolute encoder. You can clear the alarm and multi-turn data of
the absolute encoder.
Clearing of absolute encoder starts
Clearing finishes
Error occurs
(
 When non-applicable encoder is
)
  connected
Clearing of absolute encoder 
completes
<Remarks>
Don't disconnect the console from the driver between                     to                     .
Should the connector is pulled out, insert it again and repeat the procedures from the beginning.
<Notice>
If an error code No. 40 is shown on the console immediately after purchase, clear the absolute encoder 
through the console.
Press       five time after pressing       , to setup auxiliary function mode, 
then with              , make a display to
Press       to call for 
                  EXECUTION DISPLAY of
Then keep pressing       until the display of Console (LED) 
changes to 
“      ” increases by 
pressing        (approx. 5sec) 
as the left fig. shows.
SELECTION display
When you have cleared the absolute encoder, press       to return to                                  .
A incremental encoder or any 
unsupported encoder other than an 
absolute encoder may be connected. 
Reset the power supply and clear the 
error.
Operation at   SELECTION display
Operation at   EXECUTION display