Figure 36 – Top of an Open RamSan-500, Locations of the Fan 
Cages 
Please consult Figure 36 above to determine where each fan cage is in the 
chassis.  Fans 1 through 8 are in Fan Bank 1, and fans 9 through 12 are in 
Fan Bank 2. 
Once you have extracted the fan cage, find the failed fan.  There is a good 
chance that hair or dust has collected on the fan and all it needs is to be 
cleaned.  Blowing compressed air into the axle of the fan can clear 
obstruction or debris.  If the fan cannot be cleaned or repaired, the entire 
cage must be replaced. 
5.5 Batteries 
The system has two batteries; both are located directly in front of Fan 
bank 2.  These batteries are redundant and will power the entire system -  
in the event of an external power failure – long enough to copy all of the 
data in the RAM cache to the Flash storage.  Internal sensors report on 
the battery voltage level and a monthly test ensures that the current 
supplied from batteries will be able to power the system.  If the battery 
voltage is out of specification or the monthly battery test fails, warnings 
are reported.  If they degrade and are unusable, errors are reported.  The 
batteries are redundant so the cache is not at risk in the event of a power 
failure, however, replacing the failed battery quickly is recommended.  
The batters in the RamSan-500 will last on average for 2-3 years. 
 
 
Fan Bank 1 
Fan Bank 2