Anton/Bauer DUAL 2722 사용자 설명서

다운로드
페이지 15
 
 
To Operate The DDM 
1.  Mount the battery to any position on the PowerCharger.  When the PowerCharger has 
completed its communication with the battery, the ALTERNATING RED and GREEN 
LEDs will stop and the battery will begin its charge routine.  The battery information and 
position number will appear on the LCD display.  (If the battery is already on the charger, 
press the DISPLAY button until the position for the battery to be tested is displayed.) 
2.  Press the TEST button on the front panel of the PowerCharger.  An audible alert will be 
heard and the LCD will display “HOLD TEST BUTTON 3 SECONDS TO SELECT A 
TEST”. 
3.  Hold the TEST button as the unit beeps 3 times.  Release the button and the unit will 
indicate that the test mode has been selected.  This Standard test will charge-discharge-
charge the battery.  Testing time is approximately 6-8 hours per battery. 
4.  The PowerCharger will ask if the 24 hour test is desired.  If so, press the TEST button 
again to select this test.  If not, the PowerCharger will automatically begin the standard 
test.  A 24 Hour Test will charge the battery, let the battery sit for a 24 hour period, test the 
battery and then charge the battery.  This test will determine how much capacity the battery 
will lose over a 24 hour period, when not being used. 
The “RS-232 Accessory Port” on the PowerCharger transmits test information in ASCII format 
to any serial communications capable device, such as a terminal emulator or printer.  A 
personal computer serial port can also be connected and by employing any number of 
communications applications (such as PROCOMM, or Windows “Terminal”) test data can be 
saved in file format as a permanent record of battery performance. 
A serial data capable printer can be attached to the PowerCharger at the “RS-232 Accessory 
Port”, enabling the printout of hard copy of performance data from a tested battery.  The 
following is a partial list of printer manufacturer models which are compatible with the 
PowerCharger: 
•  Okidata ML 184 Turbo 
•  Okidata ML 395 
•  Panasonic KX-P3200 
Printers should be set for 1200 baud, 8 bit data length, one start bit, one stop bit.  Consult the 
printer’s owners’ manual for setup instructions. 
When testing is completed, the LCD Main Display will indicate “TEST DONE”.  To 
display or print test results: 
1.  Press the DISPLAY button on the PowerCharger front panel to scroll to the 
Primary Position Display for the battery tested. 
2.  Press the TEST button.  The LCD will display the capacity of the battery in 
ampere hours.  If a printer is attached, performance data will simultaneously be 
printed out with all battery identification information.  Consult your battery 
owners manual for warranty information and cell capacity ratings. 
Remove battery only when test data has been viewed or printed.  Test data is retained 
only while the battery is on the PowerCharger.  Once battery is removed, data is no 
longer available.