JAI CV-M7+ 사용자 설명서

다운로드
페이지 31
CV-M4
+
/M4
+
CL, CV-M7
+
/M7
+
CL
 
 
- 24 - 
 
 
7.5. CV-M4
+
 command list 
 
 
Command Name 
Format 
Parameter 
 
Remarks 
      
A – General settings and useful commands 
EB  Echo Back 
EB=[Param.]<CR><LF>  0=Echo off 
1=Echo on 
Off at power up 
ST  Camera Status request  ST?<CR><LF> 
 
 
Actual setting 
HP  Online Help request HP?<CR><LF> 
 
 
Command list 
VN  Firmware version 
VN?<CR><LF> 
 
 
3 letter version 
      B – Timing and shutter related commands 
SC  
Scanning format 
SC=[Param.]<CR><LF>  0=full frame 
2=1/4 partial 
1=1/2 partial 
3=1/8 partial 
*1) 
TR  Trigger mode 
TR=[Param.]<CR><LF>  0=normal 
2=Pulse width 
1=Edge 
3=Frame delay 
 
HC  H synchronous accum 
HC=[Param.]<CR><LF>  0=H synchr 
1= H a-synchr 
 
SM  Shutter mode 
SM=[Param.]<CR><LF>  0=Normal 1=Programmab. 
 
SH  Shutter speed 
SH=[Param.]<CR><LF>  0=Off (1/24) 
2=1/100 
4=1/400 
6=1/1500 
8=1/5500 
1=1/50 
3=1/200 
5=1/800 
7=1/3000 
9=1/10,000 
All10 steps are 
valid in normal 
trigger mode. 
 
 
PE  Programmable expos. 
PE=[Param.]<CR><LF> 
0=2.5 H,
 1=3.5H 
1055=1057.5 H 
H= 39.3 µsec 
Bin. H= 43.3 µsec.  
BI 
Binning 
BI=[Param.]<CR><LF> 
0=off 1=vertical 
*1). Only for SC=0. 
M4
+
 and M4
+
CL 
SL 
Smearless 
SL=[Param.]<CR><LF> 
0=Off 1=ON 
TR=1, 2 or 3 
RC  Reset Continuous Trig 
RC=[Param.]<CR><LF>  0=Off 1=ON 
Only for TR=1 
      C – Signals and polarity 
SO  
Sync on video 
SO=[Param.]<CR><LF>  0=no sync on v.  1=sync on v. 
Pin #4 on 12 pin
 
ML  MuLtiple shutter 
ML=[Param.]<CR><LF>  0=OFF 1=On 
Multi Trig input 
TR=3 
SE 
Sync/EEN 
SE=[Param.]<CR><LF> 
0= Sync out 
1=EEN out 
Pin #9 on 12 pin 
FP  FEN/LEN/EEN polarity 
FP=[Param.]<CR><LF>  0= active low 
1= active high 
 
TP  Trigger polarity 
TP=[Param.]<CR><LF>  0= active low 
1= active high 
*2) 
TI 
Trigger Input 
TI=[Param.]<CR><LF> 
0= Hirose 12p 
1= LVDS (CL) 
 
      D – Gain and analogue signals setting 
GA  
Manual gain Level 
GA=[Param.]<CR><LF>  0=low 510=high 
Range 0 to 510 
RP  Rear Potentiometer 
RP=[Param.]<CR><LF>  0=manual gain 
1=rear potm. 
 
SU  Setup Level 
SU=[Param.]<CR><LF>  0=low 255=high 
Range 0 to 255 
      E – Saving and loading data in EEPROM 
LD  
Load settings from 
camera EEPROM 
LD=[Param.]<CR><LF>  0=Factory data  
2=User 2 area 
1=User 1 area 
3=User 3 area 
Latest used data 
area  becomes 
default at next 
power up 
SA  Save settings to 
camera EEPROM 
SA=[Param.]<CR><LF>  1=User 1 area 
3=User 3 area 
2=User 2 area 
Parameter = 0 is 
not allowed 
EA  EEPROM area request 
EA?<CR><LF> 
0=Factory data 
3=User 3 area 
1=User 1 area 
3=User 3 area 
Return the used 
data from area 
*3) 
 
*1) 
Binning can also be selected by the internal switch SW301.6.  Binning has priority over partial scanning. If partial scanning 
is active when a binning mode is activated, binning will take over and the scanning will be full. The line frequency will be 
lower in V binning modes (H= 43.3 µsec.). 
*2) 
If positive logic is used (TP=1), the first trigger pulse after power up will be ignored. 
*3) 
Data from the latest used data area is loaded as default on power up. 
 
!! 
Do not try to use commands not shown in the list