The air filter has two kinds of filters inside. Please check and clean the air filter periodically. 
When the indicators or a message prompts you to clean the air filter, comply with it as soon 
as possible. If the filters are damaged or heavily soiled, replace them with the new ones. To 
prepare the new filters, make contact with your dealer and tell the following type number.
Type number : UX37191 (Filter set)
When you replace the lamp, please replace the air filter. An air filter of specified type will 
come together with a replacement lamp for this projector.
1.
 
 Turn the projector off, and unplug the power cord. Allow  
the projector to sufficiently cool down.
2.
 
 Use a vacuum cleaner on and around the filter cover. 
3.
 
 Slide the filter unit upward to take it off from the projector. 
4.
 
 Use a vacuum cleaner for the filter vent of the projector.
5.
 
 Take the fine meshed filter out while holding the filter 
cover. It is recommended to leave the coarse meshed  
filter in the filter cover as it is.
6.
 
 Use a vacuum cleaner on both sides of the fine meshed 
filter while holding it so it will not be sucked in. Use a 
vacuum cleaner for the inside of the filter cover to clean 
up the coarse meshed filter. If the filters are damaged  
or heavily soiled, replace them with new ones.
7.
 
 Put the fine meshed filter on the coarse meshed one, 
turning its stitched side up.
8.
 
 Put the filter unit back into the projector. 
9.
 
 Turn the projector on and reset the filter time using the 
FILTER TIME item in the EASY MENU. 
(1)  Press the 
MENU button to display a menu. 
(2)  Point at the FILTER TIME using the ▼/▲ button, then press 
the ► button. A dialog will appear.
(3)  Press the ► button to select “OK” on the dialog. It performs resetting the filter time.
Cleaning and replacing the air filter
WARNING  ►Before taking care of the air filter, make sure the power cable 
is not plugged in, then allow the projector to cool sufficiently.
►Use only the air filter of the specified type. Do not use the projector without the 
air filter or the filter cover. It could result in a fire or malfunction to the projector.
►Clean the air filter periodically. If the air filter becomes clogged by dust or the like, 
internal temperatures rise and could cause a fire, a burn or malfunction to the projector.
NOTE  • Please reset the filter time only when you have cleaned or replaced 
the air filter, for a suitable indication about the air filter.
• The projector may display the message such as the “CHECK THE AIR FLOW” 
or turn off the projector, to prevent the internal heat level rising. 
 Filter cover
Filter unit
Intake vent
Stitched
side
 Filter cover
Filter
 (coarse meshed)
Filter (fine meshed)
7.
3.