1.3
Functional Block Diagram
Configuration bus
DMA memory
transfer controller
Peripheral bus
EMAC control module
EMAC module
MDIO module
MII bus
MDIO bus
EMAC/MDIO
interrupt
DSP interrupt
controller
Introduction
shows the three main functional modules of the EMAC/MDIO peripheral:
EMAC control module
EMAC module
MDIO module
The EMAC control module is the main interface between the device core processor and the EMAC
module and MDIO module. The EMAC control module contains the necessary components to allow the
EMAC to make efficient use of device memory, plus it controls device interrupts. The EMAC control
module incorporates 8K-byte internal RAM to hold EMAC buffer descriptors.
The MDIO module implements the 802.3 serial management interface to interrogate and control up to 32
Ethernet PHYs connected to the device, using a shared two-wire bus. Host software uses the MDIO
module to configure the autonegotiation parameters of each PHY attached to the EMAC, retrieve the
negotiation results, and configure required parameters in the EMAC module for correct operation. The
module is designed to allow almost transparent operation of the MDIO interface, with very little
maintenance from the core processor.
The EMAC module provides an efficient interface between the processor and the networked community.
The EMAC on this device supports both 10Base-T (10 Mbits/sec), and 100BaseTX (100 Mbits/sec), in
either half-duplex or full-duplex mode, with hardware flow control and quality-of-service (QOS) support.
also shows the main interface between the EMAC control module and the CPU. The following
connections are made to the device core:
The peripheral bus connection from the EMAC control module allows the EMAC module to read and
write both internal and external memory through the DMA memory transfer controller.
The EMAC control module, EMAC, and MDIO all have control registers. These registers are
memory-mapped into device memory space via the device configuration bus. Along with these
registers, the control module’s internal RAM is mapped into this same range.
The EMAC and MDIO interrupts are combined into a single interrupt within the control module. The
interrupt from the control module then goes to the DSP interrupt controller.
The EMAC and MDIO interrupts are combined within the control module, so only the control module
interrupt needs to be monitored by the application software or device driver. The combined EMAC/MDIO
interrupt is connected to the DSP interrupt INT43, through the DSP interrupt controller.
Figure 1. EMAC and MDIO Block Diagram
12
Ethernet Media Access Controller (EMAC)/
SPRU941A – April 2007
Management Data Input/Output (MDIO)