Texas Instruments TMS320DM643X DMP 사용자 설명서

다운로드
페이지 120
www.ti.com
5.4
Receive Identification and Version Register (RXIDVER)
5.5
Receive Control Register (RXCONTROL)
Ethernet Media Access Controller (EMAC) Registers
The receive identification and version register (RXIDVER) is shown in
and described in
Figure 30. Receive Identification and Version Register (RXIDVER)
31
16
RXIDENT
R-0Ch
15
8
7
0
RXMAJORVER
RXMINORVER
R-0Ah
R-07h
LEGEND: R = Read only; -= value after reset
Table 29. Receive Identification and Version Register (RXIDVER) Field Descriptions
Bit
Field
Value
Description
31-16
RXIDENT
Receive identification value.
Ch
Current receive identification value.
15-8
RXMAJORVER
Receive major version value. Revisions are indicated by a revision code taking the format
RXMAJORVER.RXMINORVER.
Ah
Current receive major version value.
7-0
RXMINORVER
Receive minor version value. Revisions are indicated by a revision code taking the format
RXMAJORVER.RXMINORVER.
7h
Current receive minor version value.
The receive control register (RXCONTROL) is shown in
and described in
Figure 31. Receive Control Register (RXCONTROL)
31
16
Reserved
R-0
15
1
0
Reserved
RXEN
R-0
R/W-0
LEGEND: R = Read only; R/W = Read/Write; -= value after reset
Table 30. Receive Control Register (RXCONTROL) Field Descriptions
Bit
Field
Value
Description
31-1
Reserved
0
Reserved
0
RXEN
Receive enable
0
Receive is disabled.
1
Receive is enabled.
SPRU941A – April 2007
Ethernet Media Access Controller (EMAC)/
73
Management Data Input/Output (MDIO)