Ordering Information
E S 2 _ - _ _ _ _ - _ _ _ _
E-SAFE II = Hybrid Power Switch
Number of Poles
1
= 1 pole
2
= 2 poles controlled
3
= 3 poles controlled
Load Voltage
1
= 100 to 120VÅ(ac)
2
= 200 to 240VÅ(ac)
3
= 230/277VÅ(ac) [400/480VÅ(ac) with
wye/star, neutral connected to center
required]
Command Signal Voltage
LV = Low voltage 3 to 24VÎ(dc) or 24VÅ(ac)
HV = High voltage 100 to 240VÅ(ac)
+10/-15%, [85 to 264VÅ(ac)]
Future Option
Future Option
Custom Parameters
000 = Standard product
Any three letters or numbers = cosmetic options
Specifications
Output voltage
200/240VÅ(ac) +10/-15%, 50/60Hz, 100/120VÅ(ac)
+10/-15%, 50/60Hz
Output amperage
Up to 35A single, dual and three-phase
Operating environment
0 to 70°C (32 to 158°F) operating temperature
0 to 90% RH, non-condensing
Operational life: four million switching cycles
Installation category III, pollution degree 2
Control mode
NO-ARC hybrid contactor
Input command signal
3 to 32VÎ(dc), 24VÅ(ac) +20/-20%, off state
≤2.7VÎ(dc)
100 to 240VÅ(ac) +10/-15%, [85 to 264VÅ(ac)]
Note: On the 100 to 240VÅ(ac) input models, do not use
a RC snubber on the E-SAFE II relay input or the
temperature control command signal output.
LED indicator light
Built in LED assists in trouble shooting; LED "off" indicates
relay(s) are open, LED "on" indicates relay(s) are closed.
Input command signal terminals
1
4
in. fast on appliance
Line and load terminals
No. 10 screw will accept ring or spade,
6.35 mm (
1
4
in.) x 10-32
Mounting
Back panel mount, horizontal or vertical mounting options
6.35 mm
(0.25 in.)
97.03 mm
(3.82 in.)
82.55 mm
(3.25 in.)
140.72 mm
(5.54 in.)
 
48.51 mm
(1.910 in.)
14.88 mm
(0.586 in.)
46.99 mm
(1.85 in.)
23.88 mm
(0.94 in.)
0 0
60
Amperage
Dimensional Drawings
Ambient
Temperature
°C
5
10
15
20
25
30*
35
65
70
55
50
45
40
35
30
25
UL
®
Conditions of Acceptability
Applications must be tested as described below for specific wire
insulation or specific wire gauge sizes. Tests shall be performed in
the end application under worst case operating conditions.
Test Procedure
A. Monitor temperatures of terminals, using thermocouples between the
ring terminal and connectors L1, L2 or L3. The temperature must not
exceed 95°C (203°F).
B. Monitor temperatures of wire insulation, using a thermocouple located
three inches from the connector. The temperature must not exceed
the insulation rating of the wire.
*30A is maximum rating when operating above 240VÅ(ac).
Warning: Thermocouples attached to terminals will be at load voltage
potential, measurements need to be taken with isolated equipment or
isolate the sensor from terminal with suitable insulation.
8
AWG
90°C
Wire
10
AWG
90°C
Wire
6 AWG
90°C Wire
These ratings apply to
3-phase units with cycle
times of 30 seconds or
more. Consult the
factory for 1- and
2-phase unit ratings.
Product Rating Curve
To be automatically connected to the nearest North American Technical Sales Office:
1-800-WATLOW2 • www.watlow.com • info@watlow.com
International Technical Sales Offices:
Australia, +61-3-9335-6449 • China, +86-21-3950-9510 • France, +33 (0) 3073-2425 •
Germany, +49 (0) 7253-9400-0 • Italy, +39 (0) 2 458-8841 • Japan, +81-3-3518-6630 • Korea, +82-2-575-9804 • Malaysia, +60-3-7980-7741 •
Mexico, +52 (442) 217-6235 • Shanghai, +86-21-3950-9504 • Singapore, +65-6777-1266 • Spain, +34 91 675 1292 • Sweden, +46 35-27-11-66 •
Taiwan, +886-7-288-5168 • United Kingdom, +44 (0) 115-964-0777