Using the 7C0x SmartSwitch Hub View
2-38
Managing the Hub
Speed Selection
If you have configured the selected port as a SLIP or PPP connection, you must 
select the appropriate baud rate: 2400, 4800, 9600, 19,200, or Auto-Baud. Note that 
this field will default to Auto-Baud and become unselectable when the COM Port 
Function is set to LM or UPS.
To change any of the configuration parameters on the selected COM port:
1.
Click on the COM Port Admin: or COM Port Function: selection button to 
display a menu of available options.
2.
Drag down to select the desired setting, then release.
3.
Click on 
 to save your changes.
Enabling and Disabling Bridge Ports
For devices configured to operate as traditional bridges, you can use the Bridge 
Port menu (available in the Bridge Application Display mode) or simply click on 
any Bridge Port index or display box to enable or disable any bridging interface.
To do so:
1.
If necessary, put the Hub View into the Bridge Application Display mode (click 
either mouse button on the Module Index or Module Type box to display the 
Module menu, drag down to Application Display, then across to select 
Bridge).
2.
Click mouse button 1 on the bridge interface you wish to enable or disable; 
or
Click mouse button 3 on the bridge interface you wish to enable or disable to 
display the Bridge Port menu; drag down to Enable or Disable, as desired, 
and release.
NOTE
Current 7C0x firmware versions support only Local Management and UPS via the COM 
port; future versions will add SLIP and PPP support.
TIP
If the COM port you wish to configure is currently set to LM or UPS, the Speed Selection 
field will be unavailable until the COM Port Function is set to SLIP or PPP and that 
change is applied. Once available, the Speed Selection field will default to the last known 
speed setting; click on the field to change this setting if necessary, then click 
 
again to complete the configuration.