Disabling an Alarm
3-9
Basic Alarm Configuration
To configure additional alarms, or alarms of a different type, select the 
appropriate alarm variable at the top of the window, highlight the appropriate 
interface(s), and repeat the procedures outlined above.
Disabling an Alarm
Using the 
 button at the bottom of the window actually performs two 
functions: it both disables the alarm and deletes the alarm entry (and its 
associated event and action entries) from device memory to help conserve device 
resources. In the list box display, any “disabled” alarm automatically resets to the 
default parameters: status disabled, log yes, trap no, rising and falling thresholds 
zero, and no action.
To disable an alarm:
1.
In the top of the window, click to select the variable for which you wish to 
disable an alarm: In Octets KbTotal Errors, or Broadcast/Multicast.
2.
In the list box display, click to highlight the interface(s) for which you wish to 
disable the selected alarm type. Remember, the editable fields in the lower 
portion of the window will display the alarm parameters for the selected 
interface with the lowest index number, but the selected alarm type will be 
disabled for all selected interfaces.
3.
Click on 
. The selected alarm type on the selected interface(s) will 
be disabled, and the list box display will refresh to reflect those changes.
NOTE
When you disable an alarm, the SPMA Basic Alarm Configuration application deletes the 
alarm entry and its associated event (log and/or trap) and action (enable or disable port) 
entries from device memory. However, if any one of these delete operations fails, some 
unused entries may remain in the tables. If this occurs, you will see the following error 
message the next time you launch the Basic Alarm application or click the Refresh 
button:
To delete these unused entries and free up all available device resources, click OK; to leave 
the entries there, click Cancel. Note that this message will re-appear each time you launch 
the application or click the Refresh button until the unused entries have been removed.