3-3
Technical Overview
SMB-1 Bus
The SMB-1 is a 1 Mbps management bus located within the SmartSwitch 9000. 
This bus is utilized by all diagnostic controllers in the system including 
connectivity modules, power supply modules and the environmental module. 
The SMB-1 transports inter-chassis information between system components, 
such as power and environmental information, as well as diagnostic messages. 
Periodic loop-back tests are performed by all modules that share this bus to 
ensure the validity of SMB-1. In the event a failure is detected on SMB-1, the 
SMB-10 may be used as an alternate communication channel.
SMB-10 Bus
The SMB-10 is a 10 Mbps management bus located within the SmartSwitch 9000, 
which is also used for inter-chassis communication of modules as well as serving 
as an out-of-band management channel into the SmartSwitch 9000. The SMB-10 is 
externalized from the chassis via an optional Ethernet Port Interface Module 
(EPIM) located on the front of the Environmental Module. Through an EPIM 
connection, full SNMP management of the SmartSwitch 9000 is available out-of-
band from user data. Modules that share the SMB-10 bus periodically send out 
loop-back packets to ensure the validity of SMB-10. In the event a fault is detected 
on the SMB-10, the SMB-1 can be used as an alternate communication channel by 
the modules.
System Diagnostic Controller
This diagnostic controller is composed of a Z-80 microprocessor and its 
supporting logic. The diagnostic controller is designed to control the power-up 
sequencing of modules, monitor the 9H532-24, 9H533-24, 9H531-24 and 9H539-24 
input and output power parameters, keep watch over the main host processor, as 
well as monitor the temperature and control the SMB LANVIEW diagnostic LED. 
Although the diagnostic controller and the main host processor can operate 
independent of each other if needed, they exchange information about each 
otherÕs status and overall module condition. The information gathered by the 
diagnostic controller is available to the network manager via local/remote 
management and the LCD located on the Environmental Module. The 9H532-24, 
9H533-24, 9H531-24 and 9H539-24 have been designed so that in the event of a 
diagnostic controller fault, the 9H532-24, 9H533-24, 9H531-24 and 9H539-24 will 
continue to function.