2-4   SmartCell ZX-250 User Guide
Installing the Switch
  Switch Installation and Setup
If the switch’s hardware or software configuration is incorrect, contact Cabletron customer support immediately.
2.3.1
DS3 and E3 I/O Module Configuration
Table 2-2 shows the pre-configured values for both the DS3 (ZX-IOM-67-4) and E3 (ZX-IOM-77-4) I/O modules. 
These values cannot be changed. Accordingly, configure the connecting device’s interface to use these values.
2.4
INSTALLING THE SWITCH
SmartCell ZX-250 switches are designed to operate either while sitting on a desktop on their rubber feet or while 
mounted in a rack by side-panel mounting brackets.
2.4.1
Desktop Installation
ZX-250 switches can be installed on any clean, dry, stable surface (desktop) that allows for at least four inches of clear 
space on both sides of the switch:
U
ZX-250 — 17.5 inches wide by 14.5 inches deep
U
ZX-250r — 17.5 inches wide by 20.5 inches deep
2p›F
Because the ZX-250r power supply modules install from the back of the switch, 
you may want to select a surface that provides sufficient room to remove and 
install the power supply modules.
Table 2-2
DS3 and E3 Module settings
Protocol
Mode
Framing
Empty Cell
Timing
Scrambling
Length
DS3
plcp
cbit
unassigned
internal
off
greater than 225 ft.
E3
plcp
G.751
unassigned
internal
off
N/A