4-36 SmartCell ZX-250 User Guide
Performing Hardware Maintenance
Switch Administration
%"¤›apm
The MSM must always be replaced in the lower switch module slot, and the
ESM must always be replaced in the upper switch module slot. Placing the
boards in the incorrect slot causes the ZX-250 switch to fail.
ESM must always be replaced in the upper switch module slot. Placing the
boards in the incorrect slot causes the ZX-250 switch to fail.
Figure 4-8 Removing a switch module from the lower switch module position
4.9.8
Removing I/O Modules
s•
Ground yourself using a Cabletron-approved ESD device and appropriate safety procedures.
¢•
Once a switch module is removed from the chassis, unfasten the IOMs from the switch module (see
Figure 4-9), using a screw driver (2 screws from the bottom, 1 screw from the front).
Figure 4-9), using a screw driver (2 screws from the bottom, 1 screw from the front).
••
Remove the IOMs from the switch module (one at a time) by lifting them upward from the switch
module, disconnecting them from the switch modules’s DIN connector (see Figure 4-9).
module, disconnecting them from the switch modules’s DIN connector (see Figure 4-9).