5-4   SmartCell ZX-250 User Guide
Troubleshooting Congestion
  Troubleshooting
5.4.1
Diagnosing Congestion
s•
Enter the 
show portstats
 command, and take the default of (
all
).
¢•
If cells are not being dropped on all ports, proceed to the “Port Congestion” section.
••
If cells are being dropped on all ports, the indication is global congestion. Proceed to the “Global 
Congestion” section.
5.4.2
Global Congestion
s•
Is the total cell drop rate equal to the Unknown VC cell drop rate?
U
If yes, the switch is improperly set up. Check the switch configuration. 
U
If no, this indicates global congestion. Continue.
¢•
Set the 
porttrafficcongestion
 values to those recommended in the “QoS Queue Allocation 
Guidelines” section. Has the congestion subsided?
U
If yes, you are done.
U
If no, continue.
••
Have you changed the EPD threshold? 
U
If yes, replace it to the default setting. If congestion subsides, you are done.
U
If no, continue.
T•
Enter the 
show cacinfo
 command for each port. Is the allocated bandwidth small and is the traffic 
mostly UBR?
U
If no, go back to step 4 and check next port.
U
If yes, continue.
Q•
Enter the 
show porttrafficcongestion
 command. Is the UBR queue Max threshold large?
U
If no, go back to 4.
U
If yes, continue.
–•
Reduce the UBR queue Max threshold by a small amount, then wait a few minutes.
••
Enter the 
show portstats
 command, and take the default of 
all
. Is the number of cells dropped 
increasing for this port, and quickly decreasing for all other ports?
U
If yes, proceed to the “Port Congestion” section.
U
If no, continue.
G•
Is the number of cells being dropped by all other ports decreasing somewhat?
U
If no, go back to step 6.
U
If yes, continue.
n•
Enter the 
set caceqbwallocscheme 
command and set call admission control for this port to a more 
conservative policy (
moderate
 or 
conservative
).
s¥
Go back to step 4 until all ports have been checked.