Chapter 3: Installation
3-8
2E43-51/2E43-51R User’s Guide
3.4.3.2
Connecting Power to the 2E43-51R 
To connect the 2E43-51R to the power sources, proceed as follows: 
1.
. To 
take advantage of the load sharing and redundancy capabilities, each 
power cord must be plugged into a dedicated ac outlet. The POWER 
LED turns on (green) and the CPU LED turns on (green) briefly.
Figure 3-5
2E43-51R Rear View
2.
Observe the LANVIEW LEDs. After a successful boot, the CPU LED 
turns on (green). If the PWR LED is not green after one minute and 
turns amber, there is no power redundancy. Check the power cord 
connections and the power source. If there are no problems with the 
power cord connections or power source and the PWR LED is still not 
green, contact the Cabletron Systems Global Call Center. Refer to 
 for details.
NOTE
It takes approximately one minute for the 2E43-51R to boot up.
Primary
Redundant
8H02-26R