Lantronix SLSLP400PS201 사용자 설명서

다운로드
페이지 133
Spider™ and SpiderDuo® KVM-over-IP Device User Guide
104
11: Command Reference
This chapter lists and describes the command line interface (CLI) syntax and contains the 
following sections:
Command Syntax
Commands have the following format: <action> <category> <parameter(s)> where <action> is set, 
show, connect, diag, admin, or logout. <category> is a group of related parameters you want to 
configure or view. Examples are device, group, user, and network. <parameter(s)> is one or more 
name-value pairs in one of the following formats:
<parameter name> <aa | bb>—Specify one of the values (aa or bb) separated by a vertical 
line ( | ). The values are all lowercase and must be entered exactly as shown. Bold indicates a 
default value.
<parameter name> <Value>—Specify an appropriate value, for example, a device group 
name. This User Guide shows parameter values in mixed case to indicate they are case 
sensitive. For example, if you saved a device group name in mixed case, you must enter it in 
mixed case; if you saved it in lowercase, you must enter it in lowercase.
Square brackets [ ]—Indicate optional parameters.
Table 11-1  Action and Category
Action
Category
set
datetime | device | group | history | network | oem | power | security | serial | sshkey | user 
show
datetime | device | group | history | network | oem | power | security | serial | sshkey | 
sysconfig | user 
connect
serial | wakeonlan
diag
ping | ping6