The tables in this section list the N+1 power requirements of different EX8200 switch
configurations:
Table 26 on page 50—Lists the N+1 power requirements of EX8208 switch
configurations that use 2000 W DC power supplies.
Table 27 on page 50—Lists the N+1 power requirements of EX8216 switch configurations
that use 3000 W DC power supplies.
Table 26: N+1 Power Redundancy Configurations for Different EX8208
Switch Configurations Using 2000 W DC Power Supplies
Power Supplies
Needed for N+1
Power Supplies
Needed (N)
Input Voltage
Switch
Configuration
2
1
–40 VDC through
–72 VDC
Base
4
3
–40 VDC through
–72 VDC
Fully loaded with
8-port SFP+ line
cards
Table 27: N+1 Power Redundancy Configurations for Different EX8216
Switch Configurations Using 3000 W DC Power Supplies
Power Supplies
Needed for N+1
Power Supplies
Needed (N)
Input Voltage
Switch
Configuration
2
1
–40 VDC through
–72 VDC
Base
5
4
–40 VDC through
–72 VDC
Fully loaded with
8-port SFP+ line
cards
Related Topics
Calculating Power Requirements for an EX8216 Switch
DC Power Supply LEDs in an EX8200 Switch
A DC power supply has four LEDs on its faceplate:
FAIL
,
OUT OK
,
A IN OK
, and
B IN OK
LEDs. The text
A
or
B
next to the
OK IN
LEDs indicates which input lug the LED corresponds