Juniper Networks EX3200 사용자 설명서

다운로드
페이지 284
Mounting an EX3200 or EX4200 Switch on Four Posts in a Rack or Cabinet
You can mount an EX3200 or EX4200 switch on four posts of a 19-in. rack or cabinet
by using the separately orderable four-post rack-mount kit. (The remainder of this
topic uses “rack” to mean “rack or cabinet.”)
You can mount the switch on two posts in either a two-post rack or a four-post rack
by using the mounting brackets provided with the switch. See “Mounting an EX3200
or EX4200 Switch on Two Posts in a Rack or Cabinet” on page 118.
NOTE: If you need to mount the switch in a recessed position on either a two-post
rack or a four-post rack, you can use the 2-in.-recess front brackets provided in the
separately orderable four-post rack-mount kit.
NOTE: If you are mounting an EX4200 switch on four posts, ensure that the rack is
27.5 in. through 30.5 in. deep if you will mount the switch flush with the rack front
and that the rack is 29.5 in. through 32.5 in. deep if you will mount the switch 2 in.
recessed from the rack front, thus ensuring that the protective earthing terminal is
accessible through the opening in the rear bracket.
Before mounting the switch on four posts in a rack:
Place the rack in its permanent location, allowing adequate clearance for airflow
and maintenance, and secure it to the building structure.
Remove the switch from the shipping carton (see “Unpacking an EX3200 or
EX4200 Switch” on page 114
).
Ensure that you have the following parts and tools available to mount the switch on
four posts in a rack:
Phillips (+) screwdriver, number 2
6 flat-head 4-40 mounting screws (provided with the four-post rack-mount kit)
12 flat-head 4x6-mm Phillips mounting screws (provided with the four-post
rack-mount kit)
Mounting an EX3200 or EX4200 Switch on Four Posts in a Rack or Cabinet
121
Chapter 9: Installing the Switch