Philips PIP3202-DC 사용자 설명서

다운로드
페이지 9
Philips Semiconductors
Product specification
 TOPFET dual high side switch
PIP3202-DC 
 
 
UNDERVOLTAGE & OVERVOLTAGE CHARACTERISTICS
Limits are at -40˚C 
 T
mb
 
 150˚C and typicals at T
mb
 = 25˚C.  Refer to 
TRUTH TABLE
.
SYMBOL
PARAMETER
CONDITIONS
MIN.
TYP.
MAX.
UNIT
Undervoltage
V
BG(UV)
Low supply threshold voltage
1
2
4.2
5.3
V
V
BG(UV)
Hysteresis
0.1
0.5
1
V
Overvoltage
V
BG(OV)
High supply threshold voltage
2
35
40
45
V
V
BG(OV)
Hysteresis
0.4
1
2
V
I
BG(OV)
Operating current per channel
V
BG
 > V
BG(OV)
-
1
2
mA
OVERLOAD PROTECTION CHARACTERISTICS
Independent protection per channel.  Refer to 
TRUTH TABLE
.
5.5 V 
 V
BG
 
 35 V, limits are at -40˚C 
 T
mb
 
 150˚C and typicals at T
mb
 = 25˚C unless otherwise stated.
SYMBOL
PARAMETER
CONDITIONS
MIN.
TYP.
MAX.
UNIT
Overload protection
V
BL
 = V
BG
; t
p
 = 300 
µ
s
I
L(lim)
Load current limiting
V
BG
 
 8 V
18
30
42
A
V
BG
 = 5.5 V
15
27
42
A
Short circuit load protection
T
mb
 
 125˚C prior to overload
3
P
D(TO)
Overload power threshold
for latched protection
4
100
150
200
W
T
DSC
Characteristic time
which determines trip time
5
-
200
500
µ
s
Overtemperature protection
T
j(TO)
Threshold junction temperature
150
170
190
˚C
T
j(TO)
Hysteresis
6
3
10
20
˚C
Undervoltage sensors causes each channel to switch off and reset.
Overvoltage sensors causes each output channel to switch off to protect its load.
Above this temperature measurement of these parameters is prevented because OT protection may occur prior to SC protection.
SC protection for P
D
 > P
D(TO)
 is latched.  Normal operation may only be resumed after the input is toggled low then high again.
Normal operation is maintained as long as P
D
 < P
D(TO)
 and T
j
 < T
j(TO)
.
Trip time t
d sc
 varies with overload dissipation P
D
 according to the exponential model formula t
d sc
 
 T
DSC
 / LN[ P
D
 / P
D(TO)
 ].
After cooling below the reset temperature the channel will resume normal operation.
September 2001
5
Rev 1.000