DELL S50V 사용자 설명서

다운로드
페이지 1262
Stacking S-Series Switches | 1021
Figure 50-2.  Electing the Stack Manager
MAC Addressing on S-Series Stacks
The S-Series has three MAC addressees: the chassis MAC, interface MAC, and null interface MAC. All 
interfaces in the stack use the interface MAC address of the management unit (stack manager), and the 
chassis MAC for the stack is the master’s chassis MAC. The stack continues to use the master’s chassis 
MAC address even after a failover. The MAC address is not refreshed until the stack is reloaded and a 
different unit becomes the stack manager.
 
stack (excluding the new unit) reloads.
Note: If the removed management unit is brought up as a standalone unit or as part of a different stack, 
there is a possibility of MAC address collisions.
Stack>show system brief
Stack MAC : 00:01:e8:d5:f9:6f
--  Stack Info  --
Unit  UnitType     Status         ReqTyp      CurTyp      Version     Ports
---------------------------------------------------------------------------
  0   Standby      online         S50V        S50V        7.8.1.0     52
  1   Management   online         S50N        S50N        7.8.1.0     52
  2   Member       online         S50V        S50V        7.8.1.0     52
  3   Member       not present
  4   Member       not present
  5   Member       not present
  6   Member       not present
  7   Member       not present
Stack#show system stack-unit 0 | grep priority
Master priority : 0
Stack#show system stack-unit 1 | grep priority
Master priority : 0
Stack#show system stack-unit 2 | grep priority
Master priority : 0
Stack#show system stack-unit 0| grep "Burned In MAC"
Burned In MAC   : 00:01:e8:d5:ef:81
Stack#show system stack-unit 0 | grep "Burned In MAC"
Burned In MAC   : 00:01:e8:d5:ef:81
Stack#show system stack-unit 1 | grep "Burned In MAC"
Burned In MAC   : 00:01:e8:d5:f9:6f
Stack#show system stack-unit 2 | grep "Burned In MAC"
Burned In MAC   : 00:01:e8:cc:cc:cc