Q-Logic FIRMWARE VERSION 7.4 사용자 설명서

다운로드
페이지 84
2 – Events and Event Logging
Configuring Port Alarm Thresholds
59060-05  A
2-5
A
Configuring Port Alarm Thresholds
You can configure the switch to generate alarms for selected events. Configuring 
an alarm involves choosing an event type, rising and falling triggers, a sample 
window, and finally enabling or disabling the alarm. You can configure port alarm 
thresholds for the following port events using Enterprise Fabric Suite 2007 or the 
CLI:
„
Cyclic Redundancy Check (CRC) errors
„
Decode errors
„
Inter-switch Link (ISL) connections
„
Device logins
„
Device logouts
„
Loss-of-signal errors
To configure port threshold alarms using Enterprise Fabric Suite 2007, do the 
following:
1.
Open the Switch menu in the faceplate display, and select Port Threshold 
Alarm Configuration
.
2.
The Port Threshold Alarm Configuration dialog prompts you to enable or 
disable all alarms, select an event, set triggers, set a sample window and 
enable or disable an individual alarm. For more information, refer to the 
Enterprise Fabric Suite 2007 User Guide for your switch.
To configure port threshold alarms using the command line interface, use the 
Set Config Threshold command. For more information, refer to the Command 
Line Interface Guide 
for your switch.