Murphy LLS 사용자 설명서

다운로드
페이지 4
LLS, LLSB, LLSR, LLSRB Series Models
Lead Line Pressure Switches 
Installation and Operation Instructions 
LLS-93096N
Effective 03-94
Section 05
Description
The LLS Series is a pressure switch for applications where viscous liquids
could plug the sensing orifice. LLS and LLSB models have a 2 inch NPT
male connection which attaches directly into the process line. LLSR and
LLSRB models feature a remote sensor connected to the pressure switch by a
length of stainless steel capillary and armor. The snap-acting switch is field
adjustable. The switch is housed in a hard anodized aluminum enclosure.
Optional for LLSR and LLSRB models is a 1 inch NPT x 1 inch NPT (male)
pulsation dampener to minimize damaging pressure pulsation to the switch.
Specifications
• 
Maximum Ambient Temperature: -10° to +160°F (-23° to +71°C).
• 
Maximum Process Temperature: -40° to +160°F (-40° to +71°C).
• 
Temperature Compensation: The volumetric expansion and contraction of
the fill may cause a shift of ±3% to ±5% of the set point.
Switch Enclosure: Aluminum hard anodized (black). NEMA 4, 4x. NEMA 7
and 9 explosion-proof, waterproof and corrosion resistant. Suitable for Class I,
Div. 1, Groups A, B, C, D; Class II,  Div. 2, Groups E, F, G.
• 
Sensor Body: LLS: CRS steel chromate plated; 2 in. NPT connection.
LLSB: Thick wall 304 stainless steel sensor 2 in. NPT process connection.
LLSR: Remote Sensor; Nickel plated steel, stainless steel capillary.
LLSRB: Remote Sensor; 316 stainless steel housing and capillary.
• 
Diaphragm Materials: 
LLS/LLSB: Ni-SPAN
®
LLSR/LLSRB: 316L S. Steel–Teflon* coated. 
• 
Snap-switch Ratings: SPDT (Std.): 15 A @ 125, 250 or 480 VAC
SPDT (Gold): 100 mA @ 125 VAC; 0.250 A @ 6 VDC
DPDT (Std.): 11 A @ 125 or 250 VAC
DPDT (Gold): 100 mA @ 125 VAC; 0.250 A @ 6 VDC
• 
Trip Point Adjustment: Field-adjusted with screwdriver.
• 
LLSR/LLSRB Mount: 4-hole bolt pattern; 1/4 in. (6 mm) dia. bolts.
• 
LLS/LLSB Mount: Direct mount into process (2 in. NPT connection).
• Shipping Weight: LLS/LLSB: 4 lbs. 9 oz. (2.25 kg).
LLSR/LLSRB: 7 lbs. 12 oz. (3.23 kg).
• Shipping Dimensions: LLS/LLSB: 10 x 9-1/4 x 5-3/4 in. (254 x 235 x 146 mm).
LLSR/LLSRB: 15-3/4 x 11 x 5-1/4 in. (400 x 279 x 133 mm).
Please read the following information before installing
A visual inspection of this product for damage during shipping is recommended before mounting. 
It is your responsibility to have a qualified person install the unit and make sure installation conforms to NEC and local codes.
GENERAL INFORMATION
1
®
FRANK W.
MFR.
WARNING
BEFORE BEGINNING INSTALLATION OF THIS MURPHY PRODUCT
Disconnect all electrical power to the machine.
Make sure the machine cannot operate during installation.
Follow all safety warnings of the machine manufacturer.
Read and follow all installation instructions.
LLS Series Pressure Switch
Sensor Model Selection Table
Base
Model 
Switch Adjustment Range
Dead Band Approximate
Max System 
Wetted Parts Materials
100–1750  689 kPa–12 MPa
15–100  103 kPa–689 kPa
2500 
17.2
200–2500
13.8 MPa–17.2 MPa
20–150  137 kPa–1.03 MPa
3000 
20.6
400–4000  2.8 MPa–27.5 MPa
75–450  517 kPa–3.1 MPa
5000 
34.4
100–1750  689 kPa–12 MPa
15–100  103 kPa–689 kPa
2500 
17.2
200–2500  13.8 MPa–17.2 MPa
20–150  137 kPa–1.03 MPa
3000 
20.6
400–4000  2.8 MPa–27.5 MPa
75–450  517 kPa–3.1 MPa
5000 
34.4
CRS steel sensor –chromate plated (yellow) 
Ni-SPAN
®
diaphragm.
Thick wall 304 stainless steel sensor housing; 
Ni-SPAN
®
diaphragm. Meets NACE MR-01-75
standard for direct exposure to H
2
S.
LLS
LLSB
100–1750  689 kPa–12 MPa
15–100  103 kPa–689 kPa
2500 
17.2
100–1750  689 kPa–12 MPa
15–100  103 kPa–689 kPa
2500 
17.2
200–2500  13.8 MPa–17.2 MPa
20–100  137 kPa–689 kPa
3000 
20.6
50–450 
345 kPa–3.1 MPa
5–45 
34 kPa–310 kPa
1500 
10.3
Remote sensor–Nickel plated steel w/ stainless
steel capillary; Teflon* coated diaphragm.  
LLSR
200–2500  13.8 MPa–17.2 MPa
20–150  137 kPa–1.03 MPa
5000 
34.4
400–4000  2.8 MPa–27.5 MPa
75–450  517 kPa–3.1 MPa
5000 
34.4
Remote sensor–AISI 316 stainless steel housing;
stainless steel capillary and armor; AISI 316L
stainless steel Teflon* coated diaphragm. 
LLSRB
psi
kPa/MPa
psi
kPa/MPa
psi
MPa
Teflon–DuPont Trademark
50–450 
345 kPa–3.1 MPa
5–45 
34 kPa–310 kPa
1500 
10.3
50–450 
345 kPa–3.1 MPa
5–45 
34 kPa–310 kPa
1500 
10.3
50–450 
345 kPa–3.1 MPa
5–45 
34 kPa–310 kPa
1500 
10.3