Base I/O Address Selection
The AT-DIO-32HS device can be configured to use a base address in 
the range of 100 to 3E0 hex. The AT-DIO-32HS occupies 16 bytes of 
address space and must be located on a 16-byte boundary. Therefore, 
valid addresses include 100, 110, 120, ..., 3D0, 3E0 hex. This selection 
is software configured and does not require you to manually change any 
settings on the device.
DMA Channel Selection
The AT-DIO-32HS can achieve high transfer rates by using up to two 
16-bit DMA channels. The AT-DIO-32HS can use only 16-bit DMA 
channels, which correspond to channels 5, 6, and 7 in an AT (16-bit 
ISA) computer and channels 0, 1, 2, 3, 5, 6, and 7 in an EISA computer. 
These selections are all software configured and do not require you to 
manually change any settings on the device.
Interrupt Channel Selection
The AT-DIO-32HS increases bus efficiency by using an interrupt 
channel for event notification. The AT-DIO-32HS can use interrupt 
channel 3, 4, 5, 6, 7, 9, 10, 11, 12, 14, or 15. This selection is software- 
configured and does not require you to manually change any settings on 
the device.
Tables 2-1, 2-2, and 2-3 provide information concerning possible 
conflicts in base address, DMA channel, and interrupt channel 
assignment when configuring your AT-DIO-32HS device.
Table 2-1.  PC AT I/O Address Map
I/O Address Range (Hex)
Device
100 to 1EF
1F0 to 1F8
IBM PC AT Fixed Disk
200 to 20F
PC and PC AT Game Controller, reserved
210 to 213
PC-DIO-24 – default 
218 to 21F
220 to 23F
Previous generation of AT-MIO boards – default