Smart Switch Series Software Manual
Web-Based Management Interface
4-9
July 2005
Note: 
To allow untagged packets to participate in VLAN 2, make sure to change the Port VLAN 
Ids (PVID) for the relevant ports. Access the PVID Settings by using the VLAN ID drop down 
menu. 
Delete a VLAN Group 
Under the VLAN ID drop down menu, select the VLAN you want to remove.  
Click to select Remove VLAN. 
Click Apply. 
PVID Setting 
All untagged packets entering the switch will by default be tagged with the port’s Primary VLAN 
Identification (PVID). This screen allows you to specify the PVID for each port.  
Take VLAN 2 for example: ports 5, 6, 7, and 8 have been checked as tagged ports for this VLAN. 
You must change the PVID value from “1” to “2” for those ports to avoid losing untagged packets 
when they are received. 
Under the VLAN ID drop down menu, select PVID Setting. See below for an example of setting 
PVID for VLAN 2. 
Change the PVID value of ports 5, 6, 7, and 8. 
Click Apply.