Refer to this table and the information that follows the table to troubleshoot your hub.
Symptom
Cause 
Solution
Amber Col LED 
blinks.
There is data collision on 
the network.
Data collision is normal on Ethernet networks. 
No action is required.
Amber Col LED blinks 
excessively.
There is data collision on 
the network because the 
network is extremely 
busy 
or defective devices are 
connected on the 
network that cannot 
detect network traffic or 
collision.
Make sure connected devices are operating in 
half-duplex mode. The hub is not compatible 
with devices that operate in full-duplex mode.
If you suspect that there might be a defective 
device on the network, disconnect devices one 
at a time to isolate the defective unit on the 
network.
If the network is extremely busy, you may have 
to segment the network with an Ethernet switch 
such as a NETGEAR Ethernet switch or to 
upgrade your network to Fast Ethernet 
operation.
Wrong or miswired 
cables are used.
Make sure the correct UTP cables are used. 
See the table in the installation section of this 
guide for cable use and Normal/Uplink push 
button information. Note that home telephone 
cables can cause a collision condition and 
cannot be used in place of UTP cables.
Green Link LED is 
off when a cable is 
attached.
The port is not detecting 
a successful link.
Check for a bad cable, cable pairs that are not 
correctly wired, or loose connectors. Make sure 
that there is power to both the hub and the 
Ethernet transceiver on the connected device.
Green Link LED is not 
blinking when there is 
data transmission.
The port is not detecting 
data transmission.
Check for a bad cable, cable pairs that are not 
correctly wired, or loose connectors. Make sure 
that there is power to both the hub and the 
Ethernet transceiver on the connected device.
Green Active LED on 
the BNC port is not 
on when the port is 
connected.
The port is not detecting 
a successful link.
Make sure that each segment is terminated 
with a BNC 50 terminator at both ends. Check 
for a bad cable.
Green Rx LED on 
the BNC port is not 
blinking when there is 
data transmission.
The port is not detecting 
data transmission.
Check for a bad cable or loose connectors. 
Make sure that there is power to both the hub 
and the connected device.
Green Active LED on 
the AUI port is not 
on when the port is 
connected.
The port is not detecting 
a successful link.
Make sure that the AUI transceiver is 
functioning properly, the coaxial segment is 
terminated correctly, the segment is not 
disconnected along the cable length, and the 
signal quality error (SQE) test on the 
transceiver is disabled. Refer to your 
transceiver documentation for instructions on 
setting the SQE. 
Green Rx LED on the 
AUI port is not 
blinking when there is 
data transmission.
The port is not detecting 
data transmission.
Check for a bad cable or loose connectors. 
Make sure that there is power to both the hub 
and the connected device.
Troubleshooting Information