Use the SET BPORT_MAU SQUELCH command to establish Squelch Mode as 
either normal or low for ports on 10BASE-T SwitchModules. By default, the 
squelch level is set to normal to conform to the 10BASE-T standard. 
In general, 3Com recommends using normal squelch. Ensure the squelch level at 
both ends of the link matches. If you change the squelch level at the 
SwitchModule, you must change the squelch setting at the transceiver also.
If your network experiences too many illegally short packets (runts) in low 
squelch mode, change the setting back to normal.
Format
Example
The following command sets port 1 in slot 5 to a low squelch level:
CB5000>
 
set bport_mau 5.1.1 squelch low
    
Squelch set to LOW.
Related Command
SHOW BPORT_MAU VERBOSE
slot.port.mau
Selects a port for squelch mode setting.
slot (1 through 17) is the slot ID and port (1 through 24) is the port 
number. Use 1 as the mau variable. For example, to specify port 4 on 
the slot with slot ID 6, enter 
6.4
slot.all
Selects a slot for squelch mode setting. For example, to specify all 
ports on the slot with slot ID 6, enter 
6.all
low
Sets squelch mode to low (sensitive). Ports are able to receive weaker 
signals, allowing longer link distances. Increases the achievable link 
distance, but with the added risk of losing packets to impulse noise.
normal
Sets squelch mode to normal. Ports receive signals compliant with the 
10BASE-T standard.
set bport_mau
squelch
low
normal
slot.port.mau
slot.all