5-29
About Default Alarm Settings
A new or initialized Switch has four alarms defined 
for each port:
Bandwidth used
Broadcast bandwidth used
Percentage of packets forwarded
Errors per 10,000 packets
The default values for each of these alarms are 
given in 
.
About the Audit Log
The Switch keeps an audit log of all management 
user sessions, providing a record of changes to any 
MIB including the RMON MIB. The log can only be 
read by users at the security access level using an 
SNMP Network Manager.
Each entry in the log contains information in the fol-
lowing order:
Entry number
Timestamp
User ID
Item ID (including qualifier)
New value of item
There is a limit of 16 records on the number of 
changes stored. The oldest records are overwritten 
first.
Table 5-4   Initial settings for the default alarms
Statistic
High 
Threshold
Low 
Threshold 
Recovery
Samples 
per 
average
Period
Bandwidth 
used
Value: 85%
No action
Value: 50%
No action
4
60 secs
Broadcast 
bandwidth 
used
Value: 20%
Notify and 
blip
Value: 10%
No action
4
20 secs
Percentage of 
packets 
forwarded
Value: 85%
No action
Value: 50%
No action
4
60 secs
Errors per 
10,000 packets
Value: 200
Notify
Value: 100
No action
4
60 secs