Product Characteristics 
 
4.3 SCALANCE X208PRO 
connector 
Aging time 
Aging time 
5 minutes 
 
 
Permitted Environmental Conditions / EMC 
Operating temperature 
-20° C through +70° C 
Storage/transport temperature 
-40° C through +80° C 
Relative humidity in operation 
‹ 95% (no condensation) 
Operating altitude 
2000 m at max 56 °C ambient temperature 
3000 m at max. 50 °C ambient temperature 
RF interference level 
EN 50081-2 Class A 
Noise immunity 
EN 50082-2 
Degree of protection 
IP65 
Approvals 
UL 60950 
c-UL-us 
CSA C22.2 No. 60950 
c-Ul-us for hazardous locations  
UL 1604, UL 2279Pt.15 
FM 
FM 3611 
C-TICK 
AS/NZS 2064 (Class A). 
CE 
EN 50081-2, EN 50082-2 
ATEX Zone 2 
EN50021 
MTBF 
MTBF 
25.56 years 
Construction 
Dimensions (W x H x D) in mm 
90 x 125 x 124 
Weight in g 
950 
Installation options 
Wall mounting  
DIN rail 
ndard rail 
Order Numbers 
SCALANCE X208PRO 
6GK5208-0CA00-2AA6 
"Industrial Ethernet TP and Fiber Optic Networks" 
manual 
6GK1970-1BA10-0AA0 
IE FC Stripping Tool 
6GK1901-1GA00 
IE FC blade cassettes 
6GK1901-1GB00 
IE FC TP standard cable 
6XV1840 2AH10 
IE FC TP trailing cable 
6XV1840-3AH10 
IE FC TP marine cable 
6XV1840-4AH10 
C-PLUG 
6GK1 900-0AB00 
Power M12 cable connector PRO 
6GK1 907-0DC10-6AA3 
Signaling contact M12 cable connector PRO 
6GK1 908-0DC10-6AA3 
Power supply PS791-1PRO 
6GK5 791-1PS00-0AA6 
Power cord M12 
6GK1 907-0AF00-0AA0 
S7-300 sta
 
Industrial Ethernet SCALANCE X-100 and SCALANCE X-200 Product Line 
4-24
 
Commissioning Manual, 1,