The diagnostics over Industrial Ethernet described in the following section is possible only 
with devices of the SCALANCE X-200 product line. 
6.1 
Configuration with the Primary Setup Tool 
6.1.1 
Introduction 
Initial Assignment of an IP Address 
There are three ways of assigning an IP address to an unconfigured device, using:  
•  DHCP 
•  STEP 7 V 5.3 plus SVP 1 
•  Primary Setup Tool V3 or higher 
Before the IP address can be assigned with the setup tool, the SCALANCE X-200 must 
be accessible over Ethernet.  
•  The initial assignment of an IP address for an Industrial Ethernet switch of the 
SCALANCE X-200 product line is not possible with Web Based Management because 
this configuration tool requires that an IP address is already available.  
Supported Operating Systems 
The Primary Setup Tool can be installed and run under the following operating systems: 
•  Windows XP Professional 
•  Windows 2000 Professional SP2 
6.1.2 
Installing the Primary Setup Tool 
Procedure 
Follow the steps outlined below to install the Primary Setup Tool on your computer: 
Industrial Ethernet SCALANCE X-100 and SCALANCE X-200 Product Line 
Commissioning Manual, 1,   
6-1