Siemens SCALANCE XB-200 사용자 설명서

다운로드
페이지 60
 
Approvals 
 
SCALANCE XB-200 
Operating Instructions, 02/2015, C79000-G8976-C359-01 
55
 
ATEX (explosion protection directive) 
 
 
WARNING 
When using SIMATIC NET products in hazardous area zone 2, make absolutely sure that 
the associated conditions in the following document are adhered to: 
"SIMATIC NET Product Information Use of subasseblies/modules in a Zone 2 Hazardous 
Area". 
You will find this document 
 
on the data medium that ships with some devices. 
 
on the Internet pages of Siemens Industry Online Support 
). 
Enter the document identification number C234 as the search term. 
 
SIMATIC NET products meet the requirements of the EC directive:94/9/EC "Equipment and 
Protective Devices for Use in Potentially Explosive Atmospheres". 
ATEX classification: 
II 3 G Ex nA IIC T4 Gc 
KEMA 07ATEX0145 X 
The products meet the requirements of the following standards: 
●  EN 60079-15: 2010 (electrical apparatus for potentially explosive atmospheres; Type of 
protection "n") 
●  EN 60079-0: 2009 (Explosive atmospheres - Part 0: Equipment - General requirements) 
IECEx 
The SIMATIC NET products meet the requirements of explosion protection according to 
IECEx. 
IECEx classification: 
Ex nA IIC T4 Gc 
DEK 14.0025X 
The products meet the requirements of the following standards: 
●  IEC 60079-15 : 2010 (Explosive atmospheres - Part 15: Equipment protection by type of 
protection "n" 
●  IEC 60079-0 : 2011 (Explosive atmospheres - Part 0: Equipment - General requirements)