Siemens SCALANCE X-200 사용자 설명서

다운로드
페이지 296
 
Configuration / diagnostics using remote 
mechanisms 
6
6.1 
Assignment of an IP address 
6.1.1 
Introduction 
Initial assignment of an IP address 
 
Note 
 
The initial assignment of an IP address for an IE Switch X-200 is not possible with Web 
Based Management because this configuration tool requires that an IP address is already 
available.  
 
The IP address can only be assigned when the IE switch X-200 can be reached via Ethernet.  
There are three ways of assigning an IP address to an unconfigured device, using:  
●  DHCP 
●  STEP 7 V 5.3 plus SP 1 or higher  
If you want to assign an IP address using STEP 7, the forwarding of DCP frames to the 
relevant IE switch X-200 must not be disabled. 
●  Primary Setup Tool V3 or higher  
If you want to assign an IP address using the PST tool, the forwarding of DCP frames to 
the relevant IE switch must not be disabled. 
 
6.1.2 
Configuration with the Primary Setup Tool 
6.1.2.1 
Configuration with the Primary Setup Tool 
Primary Setup Tool (PST) 
The Primary Setup Tool is on the CD supplied with the device. 
SCALANCE X-200 
Operating Instructions, 12/2011, A5E00349864-19 
147