Siemens SCALANCE X-200 사용자 설명서

다운로드
페이지 296
 
Configuration / diagnostics using remote mechanisms 
 
6.3 Configuration using Web Based Management (WBM) and Command Line Interface (CLI) 
SCALANCE X-200 
Operating Instructions, 12/2011, A5E00349864-19 
171
 
Restart System 
Click this button to restart the IE Switch X-200. You must confirm the restart in a dialog box. 
During a restart, the IE Switch X-200 is reinitialized, the internal firmware is reloaded. The 
learned entries in the address table are deleted. You can leave the browser window open 
while the IE Switch X-200 restarts. 
Memory Reset and Restart 
Click on this button to restore the factory configuration settings with the exception of the 
following parameters: 
●  IP address 
●  Subnet mask 
●  IP address of the default router 
●  DHCP flag 
●  System name 
●  System location 
●  System contact 
●  PNIO Device Name 
●  System Event Log Table 
●  Settings for ring redundancy and standby 
An automatic restart is triggered. In the user mode, this button is invisible. 
Restore Factory Defaults and Restart 
Click this button to restore the factory defaults for the configuration. The protected defaults 
are also reset. In the user mode, this button is invisible. 
 
 
Note 
The IE Switch X-200 must be given a new IP address before it can be accessed again. 
 
Syntax of the Command Line Interface 
Table 6- 5 
System Restart & Defaults - CLI\SYSTEM\RESTARTS> 
Command 
Description 
Comment 
memreset 
Restores the factory defaults. 
The protected settings are 
retained. 
Administrator only. 
defaults 
Restores the factory defaults. 
The protected settings are also 
reset. 
Administrator only.