Product properties 
 
3.12 SCALANCE XF206-1 
 
SCALANCE X-200 
64
 
Operating Instructions, 12/2011, A5E00349864-19 
Autonegotiation 
Autonegotiation means the automatic detection of the functionality of the port at the opposite 
end. Using autonegotiation, repeaters or end devices can detect the functionality available at 
the port of a partner device allowing automatic configuration of different types of device. With 
autonegotiation, two components connected to a link segment can exchange parameters 
and set themselves to match the supported communication functionality.   
 
 
Note 
If an IE switch port operating in autonegotiation mode is connected to a partner device that is 
not operating in autonegotiation mode, the partner device must be set permanently to half 
duplex mode. 
If an IE switch port is set permanently to full duplex, the connected partner device must also 
be set to full duplex. 
If the autonegotiation function is disabled, the MDI/MDI-X autocrossover function is also 
inactive. This means it may be necessary to use a crossover cable. 
 
 
Note 
The SCALANCE XF206-1 is a plug-and-play device that does not require settings to be 
made for commissioning. 
 
MDI / MDIX autocrossover function 
The advantage of the MDI / MDIX autocrossover function is that straight-through cables can 
be used throughout and external Ethernet crossover cables are unnecessary. This prevents 
malfunctions resulting from mismatching send and receive wires. This makes installation 
much easier for the user.   
IE Switches X-200 support the MDI / MDIX autocrossover function. 
 
NOTICE 
 
Please note that a direct connection of two ports on the switch or an accidental connection 
across several switches causes a forbidden loop. Such a loop can lead to network overload 
and network failures. 
 
Auto polarity exchange 
If the pair of receiving cables are incorrectly connected (RD+ and RD- swapped over), the 
polarity is reversed automatically.