Siemens X-400 사용자 설명서

다운로드
페이지 148
Installation and Commissioning 
Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches 
C79000-G8976-C186-03 
109
6.8.3  LED Display - Power Module 
Display Modes A through C 
In display modes A through C, the two LEDs DM1 and DM2 of the Switch CPU are 
lit as described in section 6.8.2. In these three states, the status of the signaling 
contact and the presence of the supply voltages are displayed by the LEDs of the 
power module. 
 
F
L 1
L 2
P o w e r   M o d u l e   L E D s
R M
S T B Y
D M 1
D M 2
C P U   -   L E D s
P o r t   -   L E D s
P 1
P 2
D I   -   L E D s
I N 1 / I N 5
I N 2 / I N 6
I N 3 / I N 7
I N 4 / I N 8
Figure 6-25 
Example of the LED display of the power module and the Switch CPU in 
DMode A 
The following table lists the significance of the three LEDs on the power module for 
display modes A through C: 
Label Color 
Status 
Meaning 
 
off 
The SCALANCE X414-3E has not detected 
any faults, the signaling contact is closed. 
 
Red 
on 
The SCALANCE X414-3E has detected a 
fault, the signaling contact opens. 
L1 
 
off 
Power supply L1 lower than 17 V. 
 
Green 
on 
Power supply L1 higher than 17 V. 
L2 
 
off 
Power supply L2 lower than 17 V. 
 
Green 
on 
Power supply L2 higher than 17 V.