Siemens X-400 사용자 설명서

다운로드
페이지 148
Installation and Commissioning 
 
Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches 
68 
C79000-G8976-C186-03 
6.1.1  Installing / Uninstalling with an S7-300 Rail 
Installing on an S7-300 Rail 
For installation, you require a slotted screwdriver with a 5.5 mm wide blade. 
 
Notice 
When installing the SCALANCE X414-3E, hold it by the backplane and not by the 
modules, otherwise the device may be damaged. 
To install the device, follow the steps below: 
1.  Tilt the basic device slightly towards the back with the upper groove on the 
edge of the S7-300 rail and push in towards the bottom. In this position, the 
basic device should not slip off but it can be adjusted horizontally to the left or 
right until the required position is achieved. 
2.  Remove the covers from slots 7 and 9 (see section 6.2.2) and the dummy 
cover from slot 8 (see section 6.2.3). If media modules are inserted, remove 
the fast Ethernet media module instead of the cover from slot 7 (see section 
6.2.1). 
3.  Using a screwdriver with a 5.5 mm wide blade, tighten the two captive screws 
in the backplane at slot 7 and between slots 8 and 9 until the basic device can 
no longer be moved to the side. 
 
Note 
Only horizontal installation permitted (ventilation slit top/bottom).