Installation and Commissioning 
Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches 
C79000-G8976-C186-03 
89
6.5 Factory 
Defaults 
DIL Switches 
When supplied, the four DIL switches on the switch are set to OFF as default. 
 
Notice 
Before starting up for the first time, check the switch settings. 
●  RM 
is set to OFF. This means that the redundancy manager function is disabled. 
●  STBY 
is set to OFF. This switch is intended for future applications and is does not cur-
rently have any function. 
●  R1, R2 
are set to OFF. Both (electrical) gigabit ports on slot 5 are defined as ring ports. 
Further Device Properties 
With R1 and R2, ring redundancy is enabled when the device ships. 
 
Notice 
In this mode, RSTP / STP cannot be activated. 
C-PLUG 
When delivered, the C-PLUG is empty and is initialized with the factory settings 
when first started up. All subsequent configuration changes are automatically 
adopted in the internal memory of the SCALANCE X414-3E and in the C-PLUG.