StarTech.com SV3253DXI 사용자 설명서

다운로드
페이지 74
Instruction Manual
9
The following are the factory default values for the WAN port:
    IP Address: 192.168.1.123
    Subnet Mask: 255.255.255.0
    Default Gateway: 192.168.1.254
    Broadcast: 192.168.1.255 
To access the Web configuration for this product, you will need to con-
figure the workstation you are using to the same subnet (255.255.255.0) 
and also assign it a valid IP address (i.e. 192.168.1.100). For details on 
how to change the IP address of your computer (if necessary), consult 
your documentation or System Administrator for assistance.
 
Please note:
In order to avoid a conflict, it is advisable to verify whether another  

  device on your network is using the same IP address as the  
  SVxx53DXI before connecting it to the network. 
Should an IP address conflict occur with another device on the  

  network, power off the conflicting device or assign it another IP address  
  before continuing the installation.
If you are configuring more than a single SVxx53DXI unit using the  

  factory default settings on the WAN port, they cannot be connected to  
  the network at the same time, as they will use the same IP address.
Not all IP addresses are valid for a given subnet. If you are required  

  to change your subnet (and therefore IP address) to configure the unit,  
  be sure the IP address you choose is within the allowable range for the  
  255.255.255.0 subnet.
Once your computer is configured to the same subnet as SVXX53DXI, 
you can use the IP address 192.168.1.123 to access the Web configura-
tion system.