Sun Microsystems 816-0830-12 사용자 설명서

다운로드
페이지 236
64
Sun StorEdge Network FC Switch-8 and Switch-16 Installation and Configuration Guide • October 2001
b. Enter the switch IP address in the Fabric window of the GUI.
It may take a few seconds for the switch icon to become gray. You can click the
Refresh button.
c. After the switch icon becomes gray, click the Sun logo.
Note –
If the icon remains red, it is likely that the IP address is wrong, or that the
switch cannot be accessed from that subnet, or the switch lacks power or an ethernet
connection.
To Verify and Load the Switch Firmware
You must have the correct firmware revision for the 3.0 version of the GUI in each
switch of the Fabric. For cascaded switches, both switches must have the same
firmware revision.
To Verify the Firmware Revision Level of the switch(es):
Perform the following procedure for each switch.
1. Verify that the switches are not connected to each other.
2. Connect one switch to the net.
3. Launch the GUI and bring up the switch.
4. Open the Topology View screen.
The switch icon representing the connected switch displays in the right window
pane.