Avaya 580 사용자 설명서

다운로드
페이지 782
Document No. 10-300077, Issue 2
8-35
Configuring Ports
CLI Command
To configure switch ports using the CLI, use the following CLI command: 
(configure)# 
set port <options>
* Note:  See the examples later in this section for recommendations on 
how to set particular trunk port connections.
* Note:  See “
” in 
 for more information on 
creating VLANs.
Automatic VLAN Creation
Automatic VLAN creation is done by enabling the Automatic VLAN 
Creation parameter on an individual port under the ‘Module & Ports > 
Configuration > Switch Ports > name menu. With this parameter enabled, 
the port will automatically create a VLAN each time it receives a frame 
from an unknown VLAN ID in received IEEE 802.1Q and Multi-Layer 
tagged frames. 
* Note:  The automatic VLAN creation feature does not create entries in 
3Com Mapping Tables. 
When a VLAN is created automatically the VLAN name and VLAN ID are 
derived from the received tagged frame. The VLAN name will be created as 
*autoVlan <VLAN ID>. The VLAN ID will be identical to the VLAN ID of 
the received tagged frame. As with all VLANs, the VLAN name may be 
modified to something more descriptive.   
 shows the Avaya P580 and P882 Multiservice switch VLAN 
table. The VLANs Default and Discard are permanent VLANs assigned to 
every switch. VLAN Net90 is a manually created VLAN, while VLAN 
*autoVlan1001 was created automatically by software.
 describes the VLAN Binding field options.
Automatic VLAN 
Creation
Enable (Disable if using VTP Snooping) - Causes the 
switch to learn new VLAN IDs that arrive at the port, and 
then bind the port to these VLANs.
VTP Snooping
Enable - Causes the switch to update its VLANs as they 
are created, deleted, or changed on the Catalyst.
Table 8-7.  Example 1. Trunk to Cisco Catalyst 5000
TM
Parameter
Recommended Setting
2 of 2