Document No. 10-300077, Issue 2
8-47
Configuring Ports
Network Error Detection and Recovery
Overview
Functionality
The Network Error Detection and Recovery (NEDR) feature monitors 
Ethernet CRC errors on Ethernet data ports and compares the rate of errors 
that occurs to the threshold values that you set. This feature helps you find 
the source of the errors and take corrective action if necessary. 
If the rate of CRC errors equals or exceeds the threshold value, the NEDR 
feature can: 
Disable the port
Log the event in the event log
* Note:  The Link LED on the 10-Gigabit module does not indicate a 
disabled status. The LED should flash green when you or the 
Network Error Detection and Recovery (NEDR) feature disable 
the port. However, the LED remains solid green. 
If NEDR shuts down a port, the switch will forward traffic through a 
redundant port if you: 
Enable a protocol that supports redundancy, such as OSPF, VRRP, 
or STP, on the port 
Provide an alternate path
If you do not enable a protocol that supports redundancy on the port and 
provide an alternate path, you may lose traffic if the port shuts down. 
If you replace a module that has a port that NEDR has disabled, the switch 
will load the startup configuration for the module and reenable the port. 
However, if you save the running configuration to the startup configuration 
while a port is shut down, you will have to manually reenable the port after 
you replace the module or reset the switch. 
To reenable a turned off port, use the set port enable
 
CLI command.