User Guide for the Avaya P580 and P882 Multiservice Switches, v6.1
Chapter 10
WARNING:
Figure 10-5.  Switch Fabric Status Web Page
If a redundant controller is installed in the switch and enabled, the switch 
resets and the redundant controller automatically takes over the operation of 
the failed Primary controller.
To replace the failed Primary controller:
1.  Disable redundant hardware.
2.  Copy the running config to the startup config.
3.  Synchronize if you have redundant supervisor modules.
4.  Power off the switch power supplies.
To avoid bodily harm and equipment damage, you must power off the 
switch before you remove switch controllers or elements.
5.  Replace the failed controller.
6.  Power on the switch power supplies and login.
7.  Enable the redundant hardware (see “
earlier in this chapter).
8.  In the navigation pane, click Switch Fabric again (System > 
Configuration folders). The Switch Fabric Status Web page redisplays 
with the Switch Controller field displaying:
# 1 Active