Avaya 580 사용자 설명서

다운로드
페이지 782
Document No. 10-300077, Issue 2
10-13
Configuring Redundancy Options
Supervisor Module Redundancy Statistics 
The active supervisor periodically sends a health report message to the 
standby (redundant) supervisor. If the standby supervisor is enabled, it 
responds with a health report reply.
Health report statistics are displayed on the CPU Redundancy Status Web 
page. To view this Web page, expand the System > Configuration > CPU 
Redundancy
 folders, and then click Status/Statistics. The following 
statistics are displayed:
Health Reports Sent - Displays the number of health reports sent.
Health Reports Received - Displays the number of health reports 
received.
Health Reports Timeouts - Displays the number of health reports 
timeouts.
Health Reports Missed - Displays the number of health reports 
missed.
Click REFRESH to reset all CPU redundancy statistics.
Active and Standby Roles
 shows possible supervisor configurations and, for each 
configuration, which supervisor is active and which is standby. 
Table 10-1.  Supervisor Module Configurations
Configuration
Active and Standby Role
One supervisor in slot 1
The slot 1 supervisor module is active. 
If a supervisor module is inserted into slot 2, the slot 
1 supervisor module remains active and sends health 
reports to the standby supervisor in slot 2.
1 of 2