Avaya 580 사용자 설명서

다운로드
페이지 782
Document No. 10-300077, Issue 2
23-7
Using RMON and Ethernet Statistics to Analyze Network Performance
CLI Command
To view network statistics using the CLI, enter the following command in 
Privileged mode:
(configure)# 
show ethernet counters <cr | mod-num | mod-swport-
spec>
Setting Up Port Mirroring
Configuring an RMON mirror port allows you to mirror traffic from a port 
or set of ports to a specific mirror port, where you can attach a sniffer or 
RMON probe. The switch supports a single mirror port and a single source 
port for each switch fabric port. For example, 20-port Fast Ethernet cards 
have two fabric ports (one for ports 1 through 10, one for ports 11 through 
20). You can set up a single source port and a single mirror port for each set 
of ports associated with a fabric port. You can also choose to mirror all 
traffic from a particular fabric port to the mirror port, or set up multiple 
source ports to mirror traffic to a single mirror port. 
Collisions (half-
duplex links only)
Counts number of times that packets 
have collided on the network. 
Collisions increase as network use of 
shared segments increases. Therefore, 
if the collision rate increases without 
an increase of network use, it might 
indicate a problem. Guidelines for 
appropriate collision rates are:
• 10 percent: Normal collision rate 
for shared Ethernet segment.
• 30 percent: Collisions begin to 
interfere with performance.
• 70 percent: Practical limit for 
network to remain functioning. 
A full-duplex link should not show 
collision activity. Collisions are rare in 
a switched network, unless your 
switched segments attach to multiple 
ends stations (a legal configuration 
option).
Collisions do not occur on fiber optic 
cable and thus do not occur on the 10-
Gigabit module.
Possible causes:
• Busy network
• Broken adapter (not listening before 
broadcasting)
• Network loop
Possible actions (respectively)
• If you have multiple stations on a 
switch segment, reconfigure network 
into segments with fewer stations. 
• Isolate each adapter to see if the 
problem ceases. 
• Activate spanning tree to resolve loops 
automatically.
• Ensure that there are no connections to 
the same station where both 
connections are simultaneously 
active.
Table 23-1.  Ethernet Interface Statistics Web Page Fields
Statistic
Indicates
Actions
4 of 4