Avaya M770 사용자 설명서

다운로드
페이지 338
Chapter 20
Signaling Security (Access Control) Commands
Avaya M770 ATM Switch User’s Guide
257
Signaling Security Event Log and Traps
The Signaling Security feature keeps track of access control violation attempts. 
Every time a call setup is being rejected due to access control violation an event is 
logged. Up to 100 most recent events are logged (i.e. if the log is full and a call is 
being rejected an event will be logged and the oldest event will be removed).
Note:  
Access control violation events are not saved in a non-volatile memory.
Signaling Security Traps Management
The switch can either send or not send SNMP traps to the NMS in case access 
control violation attempt occurs. The SNMP trap contains information about the 
violation attempt.
Enabling/Disabling Signaling Security related SNMP traps:
Displaying event logs
Command:
M15-155s8:/> vport sig sigsecurity traps enable  
Command:
M15-155s8:/> vport sig sigsecurity traps disable
Command:
M15-155s8:/> vport sig sigsecurity event show 
Output
vport:          9.13.0
direction:      outgoing
srcnsap:         
39.02.02.00.00.00.00.00.00.00.00.00.00.00.00.f6.00.01.3c.82
dstnsap:         
39.00.00.00.00.00.00.00.40.0d.87.00.2c.00.40.0d.87.00.2c.82
filter priority:255
template:       Base
ruletime:       08:42:02 01 Jun 2000 GMT
-------------------
vport:          9.1.0
direction:      incoming
srcnsap:         
39.00.00.00.00.00.00.00.40.0d.87.00.2c.00.40.0d.64.03.ea.81
dstnsap:         
39.01.01.00.00.00.00.00.00.00.00.00.00.00.40.0d.87.00.4e.86
filter priority:10
template:       block-1
time:           00:00:49 01 Jan 1970 GMT