Avaya P130 사용자 설명서

다운로드
페이지 160
Chapter 4        Installation and Setup
Avaya P130 User’s Guide
19
Figure 4.5
Avaya P133GT2 Module
Front-Panel Pushbuttons
Two pushbuttons, Left and Right, are used to select the function to be shown 
simultaneously on all Port LEDs. The current function selected is indicated by a lit 
Function LED.
When you press both Left and Right pushbuttons simultaneously for 1.5 seconds 
then the module is reset. The LEDs are described on Page 12.
Configuration Symbol
The Configuration Symbol (C/S) of the P130 module is the hardware version 
number and can be found either via the MultiService Network Manager application, 
via the CLI, or on a label on the module.
Serial Number
The P130 Serial Number is a unique number allocated to a specific P130 module. 
This 7-digits number is shown on a label on the module and can be found using the 
MIB item - genGroupSerialNumber.
Power Supply
The P130 110/220 VAC power inlet is at the back of the box.
P130/P330/P120 Back-up Power Supply (BUPS)
The P133G2 and P134G2 modules have a Back-Up Power Supply (Female D-Type 
connector) connector on their back panels. You can use the same BUPS unit for the 
P130, P330 and P120 switches.
The BUPS input is 150 W @ 5 V DC and operates in load power sharing mode with 
the internal P130 module power supply (See: P133G2/P134G2 AC Back Panels on 
Page 13).