Cajun P550/P880 Manager User Guide
Configuring the Cajun Switch Using the P550/P880 Manager
              2-37
Figure 2-10.  Temperature System Dialog Box
Table 2-8.  Temperature Threshold Parameters
Threshold
Defines...
 High Shutdown 
Temperature 
(Layer 2)/High 
Warning 
Temperature 
(Layer 3)
The value in degrees Celsius that when passed 
causes the switch to send a trap to the network 
management station and triggers a shutdown. 
By default, this value is 50 degrees Celsius. For 
the Layer 3 CPU sensor, the default value is 100 
degrees Celsius.
Upper Warning 
Temperature
The value in degrees Celsius that when passed 
causes the switch to send a warning that the 
temperature is approaching the high 
temperature threshold. By default, this value is 
45 degrees Celsius. For the Layer 3 CPU sensor, 
the default value is 85 degrees Celsius.
Lower Warning 
Temperature
The value in degrees Celsius that when passed 
causes the switch to send a warning that the 
temperature is approaching the low 
temperature threshold. By default, this value is 
5 degrees Celsius.
Low Shutdown 
Temperature 
(Layer 2)/
Low Warning 
Temperature 
(Layer 3)
The value in degrees Celsius of how low the 
temperature must drop on the switch to reset 
the warning and high thresholds. This value 
prevents the switch from sending traps 
continually if the temperature is hovering 
around the threshold value. By default, this 
value is 0 degrees Celsius.