McDATA 3032 사용자 설명서

다운로드
페이지 612
4
Power-On Procedure
4-41
Repair Information
2. Disconnect the fiber-optic cable from the SFP. Use compressed air 
to blow any contaminants from the connector as shown in part A 
of 
.
— Keep the air nozzle approximately 50 millimeters (two inches) 
from the end of the connector and hold the can upright.
— Blow compressed air on the surfaces and end of the connector 
continuously for approximately five seconds
.
Figure 4-24
Clean Fiber-Optic Components
3. Gently wipe the end-face and other surfaces of the connector with 
an alcohol pad as shown in part B of 
. Ensure the pad 
makes full contact with the surface to be cleaned. Wait 
approximately five seconds for surfaces to dry.
4. Repeat 
 and 
 of this procedure (second cleaning).
5. Repeat 
 and 
 of this procedure again (third cleaning), 
then reconnect the fiber-optic cable to the port.
Power-On Procedure
To power on the switch:
1. One alternating current (AC) power cord is required for each 
power supply. Ensure power cord(s) are available to connect the 
switch to facility power.
A
B