Allied Telesis AT-8000S 사용자 설명서

다운로드
페이지 48
Page 24
  
Allied Telesis AT-8000S Switch 
Switch Installation Guide
Caution
Installation of the equipment in a rack should be such that the amount of air flow required for safe operation 
of the equipment is not compromised.
 
E36
Warning
Reliable earthing of rack-mounted equipment should be maintained. Particular attention should be given 
to supply connections other than direct connections to the branch circuits (e.g., use of power strips).
 
E37
Warning
To reduce the risk of electric shock, the PoE ports on this product must not connect to cabling that is routed 
outside the building where this device is located. 
 
E40
Site Requirements
The device should be placed on a table-top. Before installing the unit, verify that the location chosen for 
installation meets the following site requirements.
General — Ensure that the power supply is correctly installed.
Power — The unit is installed within 1.5 m (5 feet) of a grounded, easily accessible outlet 100-250V AC, 50-
60Hz.
Clearance — There is adequate frontal clearance for operator access. Allow clearance for cabling, power 
connections, and ventilation.
Cabling — The cabling is routed to avoid sources of electrical noise such as radio transmitters, broadcast 
amplifiers, power lines, and fluorescent lighting fixtures.
Ambient Requirements — The ambient unit operating temperature range is 0 to 40ºC (32 to 104ºF) at a 
relative humidity of up to 95%, non-condensing. Verify that water or moisture cannot enter the device casing.
Unpacking
This section contains information for unpacking the device, and includes the following topics: