Chapter 3. Configuration
3-4
MX2800 STS-1 User Manual
61200659L1-1
signal or reception of AIS will cause the unit to enter hold-over 
mode. The STS-1 receive signal must be valid for at least 10 
seconds for the unit to exit hold-over mode and restore loop timing. 
When the unit is configured for 
F
REE
-R
UN
 timing mode, timing is 
derived from a +/-20 ppm internal reference providing a SONET 
Minimum Clock (SMC). 
Setting the unit to 
E
XTERNAL
 timing mode configures the unit to 
derive clocking from one of the two external sources selected in the 
P
RI
 E
XT
. C
LOCK
 and 
S
EC
 E
XT
. C
LOCK
 options. These two entries 
select which of the 28 active T1/E1 ports will be used as the 
external clock source. The external clock source may be disabled (if 
only one source exists, or no external clock sources are desired). A 
valid clock source is one on which neither LOS or AIS conditions 
exist. The selected T1/E1 may be a data carrying tributary. When 
both sources are configured, failure of one source will cause the 
unit to switch to the other source (if it is a valid source). Failure of 
both sources will cause the unit to enter hold-over mode. At least 
one external clock source must be valid for at least 10 seconds for 
the unit to exit hold-over mode and restore external clock timing. 
XCV Threshold
The 
XCV T
HRESHOLD
 (excessive code violations threshold) sets a 
limit on code violations accepted by the unit before it switches 
controller cards. If set to 
D
ISABLED
, code violations will not cause 
the unit to switch controller cards. The threshold limits are 
described in the following chart:
Switching between 
P
RI
mary and 
S
EC
ondary external clock sources 
is non-reverting.