The ADTRAN system chassis frame ground 
terminal must be connected to a reliable earth 
ground to ensure that the metal enclosure of the 
SFP is properly grounded via the backplane 
connector.
NOTE: The 3.125 Gigabit Ethernet port(s) are optical and 
therefore are not classified as any type of port as 
defined in Appendix B of GR-1089-CORE Issue 4.
The SFP is designed to meet the following environmental 
classes:
ETSI EN 300 019-1-1 “Classification of 
environmental conditions; Storage,” Class 1.2
ETSI EN 300 019-1-2 “Classification of 
environmental conditions, Transportation,” Class 2.3
ETSI EN 300 019-1-3 “Classification of 
environmental conditions, Stationary use at weather-
protected locations,” Class 3.3
The equipment is designed to function without degra-
dation during exposure to all test severities per Class 3.3.
COMPLIANCE
CAUTION: Electrostatic Discharge (ESD) can damage 
electronic modules. When handling modules, 
wear an antistatic discharge wrist strap to 
prevent damage to electronic components. Place 
modules in antistatic packing material when 
transporting or storing. When working on 
modules, always place them on an approved 
antistatic mat that is electrically grounded.
The SFP is a Class 1 Laser Product and complies 
with the Laser Safety requirements of FDA 
21CFR 1040.10 and 1040.11, and EN60825-1 
and -2. The SFP is NRTL Listed and CB Certified 
to all applicable American and European safety 
standards. 
The SFP meets or exceeds all the applicable 
requirements of NEBS, Telcordia GR-63-CORE, 
and GR-1089-CORE. The SFP is intended for 
deployment in Central Office type facilities, 
EEEs, EECs, and locations where the NEC 
applies (for example, Customer Premises). The 
SFP is to be installed in ADTRAN products in 
Restricted Access Locations only, and installed 
by trained service personnel. 
This device complies with Part 15 of the FCC rules. 
Operation is subject to the following two conditions:
1. This device may not cause harmful interference
2. This device must accept any interference received, 
including interference that may cause undesired 
operation.
Changes or modifications not expressly approved by 
ADTRAN could void the user's authority to operate this 
equipment.
CAUTION: Per GR-1089-CORE the ADTRAN system that 
the SFP is being deployed in is designed and 
intended for installation as part of a Common 
Bonding Network (CBN). The ADTRAN system 
that the SFP is being deployed in is not designed 
nor intended for installation as part of an 
Isolated Bonding Network (IBN).
Per GR-1089-CORE Section 9, the SFP does not 
have an internal DC connection between battery 
return and frame ground. The SFP can be 
installed in a DC-I (isolated) or DC-C (common) 
installation. For installations where other cards 
or the host system have internal connections 
between battery return and frame ground, the 
system would be intended for deployment only 
in a DC-C installation.
Warranty
: ADTRAN will replace or repair this product within the warranty period if it does not meet 
its published specifications or fails while in service. Warranty information can be found 
online at 
www.adtran.com/warranty
.
© 2008 ADTRAN, Inc. All Rights Reserved.
*61442880G1-22A*
C A U T I O N ! 
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY.
HANDLING PRECAUTIONS REQUIRED.
CLEI: SOOTAKEJ_ _
Product P/N: 1442880G1
Issue Date: 0804
Document P/N: 61442880G1-22A
PRICING AND AVAILABILITY
800.827.0807
TECHNICAL SUPPORT
800.726.8663
RETURN FOR REPAIR
256.963.8722
Small Form-Factor Pluggable
3.125 Gigabit Ethernet 80 km